CBDGR - 1,2-BENZENEDICARBONYL DICHLORIDE, 0-137

  • MSDS: CBDGR
  • Manufacturer: CHEM SERVICE INC
  • Product Name: 1,2-BENZENEDICARBONYL DICHLORIDE, 0-137
  • National Stock Number: 6810-00N066138
Product Identification

Product ID:1,2-BENZENEDICARBONYL DICHLORIDE, 0-137
MSDS Date:09/01/1988
FSC:6810
NIIN:00N066138
MSDS Number: CBDGR

Responsible Party
CHEM SERVICE INC
WEST CHESTER, PA 19381
US

Emergency Phone: 215-692-3026

Info Phone: 215-692-3026

Cage: 84898

Contractor
CHEM SERVICE, INC
599 WEST CHESTER, PA 19301-9650 US

Telephone: 610-692-3026

Cage: 8Y898

Ingredients

1,2-BENZENEDICARBONYL DICHLORIDE

CAS: 88-95-9

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE. CONTACT LENSES SHOULD NOT
BE WORN IN THE LABORATORY. ALL CHEMICALS SHOULD BE CONSIDERED
HAZARDOUS-AVOID DIRECT PHYSICAL CONTACT! ACUTE:LACHRYMATOR-CAUSES
SEVERE EYE IRRITATION. VAPORS AND/O R DIRECT EYE CONTACT CAN CAUSE
SEVERE EYE BURNS. CAN CAUSE SEVERE SKIN BURNS. INGESTION MAY CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SEVERE CORROSION OF THE MOUTH. DUST
AND/OR VAPORS CAN CAUSE IRRITATION TO RESPIRATORY TRACT. CAN BE
IRRITATING TO MUCOUS MEMBRANES. EXTREMELY DESTRUCTIVE OF MUCOUS
MEMBRANES AND/OR UPPER RESP IRATORY TRACT.
Medical Cond Aggravated by Exposure:NOT RELEVANT.

First Aid

First Aid:ANTIDOTE IS SUBSTANCE INTENDED TO COUNTERACT EFT OF POISON.
IT SHOULD BE ADMIN ONLY BY PHYS/TRAINED EMER PERS. MED ADVICE CAN
BE OBTAINED FROM POIS CTL CTR. INGEST:CALL MD IMMEDIATELY .
EYES:FLU SH CONTINUOUSLY W/WATER FOR @ LEAST 15 MINS. SKIN:FLUSH
W/WATER FOR 15-20 MINS. IF NO BURNS HAVE OCCURRED-USE SOAP & WATER
TO CLEANSE SKIN. INHAL:REMOVE PATIENT TO FRESH AIR. ADMIN OXYG IF
(SUPDAT)

Fire Fighting

Flash Point:234F,112C
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL POWDER. DO NOT USE
WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:EVAC AREA. WEAR APPROP OSHA-REGULATED EQUIP.
VENTILATE AREA. ABSORB ON VERMICULITE OR SIMILAR MATERIAL. SWEEP UP
& PLACE IN AN APPROP CNTNR. HOLD FOR DISPOSAL. WASH CONTAMD
SURFACES TO REMOVE ANY RESI DUES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE APPROP NIOSH/MSHA APPRVD SFTY
EQUIP. AVOID CONT W/SKIN, EYES & CLTHG. KEEP TIGHTLY CLSD & STORE
IN COOL DRY PLACE. STORE ONLY W/COMPAT CHEMICALS.
Other Precautions:PERSONS NOT SPECIFICALLY & PROPERLY TRAINED SHOULD
NOT HNDL THIS CHEM/ITS CNTNR. THIS PROD IS FURNISHED FOR LAB USE
ONLY! OUR PRODS MAY NOT BE USED AS DRUGS, COSMETICS,
AGRICULTURAL/PESTICIDAL PRODS, FOOD ADDITIVES/AS HOUSEHOLD
CHEMICALS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:HOOD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGG & (SUPDAT)
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:PATIENT IS HAVING DFCLTY BRTHG. IF PATIENT HAS STOPPED
BRTHG ADMIN ARTF RESP. IF PATIENT IS IN CARD ARREST ADMIN CPR.
CONTINUE LIFE SUPPORTING MEASURES UNTIL MED ASSISTANCE HAS ARRIVED.
GET MED ATTN IF NEC. DO NOT WEAR SHOES/CLTHG UNTIL ABSOLUTELY FREE
OF ALL CHEM ODORS. EYE PROT:FULL LENGTH FSHLD.

Chemical Properties

Boiling Pt:B.P. Text:>516F,>269C
Melt/Freeze Pt:M.P/F.P Text:53.6F,12.0C
Vapor Density:1.409
Evaporation Rate & Reference:NOT KNOWN.
Solubility in Water:NOT KNOWN.
Appearance and Odor:COLORLESS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
REACTS W/WATER & MOST REACTIVE HYDROGEN CMPDS. REACTS W/ALCOHOLS.
INCOMPAT W/STRONG OXIDIZING AGENTS, STRONG BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:BURN IN A CHEMICAL INCINERATOR EQUIPPED WITH AN
AFTERBURNER AND SCRUBBER. DISPOSAL MUST BE I/A/W FEDERAL, STATE &
LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.